A bathroom fan is sized by the room, and the size is measured in CFM — cubic feet per minute, the volume of air the fan moves. The guidance from the Home Ventilating Institute is simple: one CFM per square foot of bathroom, with a minimum of 50 CFM for a small bathroom. A bathroom of 50 square feet needs a 50 CFM fan; a bathroom of 100 square feet needs a 100 CFM fan. That is the whole sizing rule, and it is the rule this guide works through.
The size matters because the fan is the bathroom's only way out for steam. A shower fills the room with warm, wet air, and that air has to leave — through the fan, down a duct, and outside the house. A fan too small for the room leaves the air behind: the mirror stays fogged, the grout stays damp, and the mold that feeds on damp grout comes back to the same lines within weeks. A fan that is sized right and run long enough clears the room, and the grout dries between showers.
Worcester's housing makes the fan question harder than it looks. The city's older bathrooms were built with fans that vent into the attic, or with no fan at all and a window instead — and both of those are mistakes this guide explains. A fan that vents into the attic moves the moisture to the roof sheathing, where it rots the wood out of sight. A window is not ventilation unless it is large enough and opens far enough. The guide below works through the size, the run time, the duct, and the window rule, in that order.
TL;DR
Problem: A bathroom fan that is too small, or ducted into the attic, leaves the grout damp — and damp grout grows mold that keeps coming back.
Solution: Size the fan at one CFM per square foot of bathroom, with a minimum of 50 CFM, duct it outside the house, and run it during and for 20 to 30 minutes after every shower.
When to call: When the mirror stays fogged, the grout stays damp, or the fan vents into the attic — the visit reads the fan, the duct, and the room together.
Fan sizing by the numbers
The Home Ventilating Institute guidance is one CFM per square foot of bathroom floor, with a minimum of 50 CFM. A bathroom of 40 square feet — the common 5-by-8 bathroom — needs a 50 CFM fan, because the minimum applies. A bathroom of 80 square feet needs an 80 CFM fan. A bathroom of 120 square feet needs a 120 CFM fan. The measure is the floor: length times width, in square feet, and the fan's CFM rating should match it or exceed it. A fan rated below the room's size will run and run and never clear the air, because it moves less air than the shower puts into the room.
How long the fan should run
The fan should run during the shower and for 20 to 30 minutes after every shower. The steam that fills the room during a shower does not leave when the shower stops — it sits in the air, on the mirror, and in the grout, and it needs half an hour of steady air movement to leave. A fan switched off with the shower leaves the room wet. A timer control, or a humidity-sensing control that runs the fan until the air is dry, takes the decision out of the household's hands: the fan runs until the room is dry, and then it stops. The visit reads the controls as well as the fan, because a fan with no timer is a fan that gets switched off too early.
The attic-venting mistake
A bathroom fan must be ducted outside the house — through the wall or through the roof — and never into the attic. A fan that vents into the attic moves the moisture from the bathroom to the roof sheathing, where it condenses on cold wood, rots the sheathing, and grows mold out of sight. The bathroom looks dry and the attic rots. The mistake is common in Worcester's older homes, where the fan was installed before the ducting rules were what they are now, and it is found by looking in the attic rather than in the bathroom. The visit reads the duct as well as the fan, and the duct must end outside.
Windows are not ventilation
A window is not ventilation unless it meets the rule. The building code's rule is a window of at least three square feet, with at least half of it openable — or, where there is no window that meets the rule, an exhaust fan of 50 CFM intermittent or 20 CFM continuous. A small window that opens a crack is not ventilation; a window that does not open at all is not ventilation. In winter, a window that must be opened to ventilate a bathroom is a window that lets the cold in and the steam out in the wrong order. The fan is the ventilation; the window is a second way out, not a substitute.
How to tell if the current fan is too small
The signs are plain. The mirror stays fogged long after a shower. The grout stays dark hours after the room was used. Mold returns to the same grout lines within weeks of cleaning. The fan itself is loud and moves little air — a fan that hums and barely pulls a tissue to its grille is a fan that has lost its rating to age, dust, or a crushed duct. The visit reads the fan's rating, the duct, and the room together, because a fan that is sized right but ducted wrong is a fan that still fails, and a fan that is ducted right but sized wrong is a fan that still leaves the room damp.
What the visit covers
The visit for a fan question reads the room, the fan, and the duct. The room is measured so the fan can be sized. The fan is read for its rating and its age. The duct is traced to where it ends — outside the house, or into the attic. The controls are read: a timer or a humidity-sensing control, or a plain switch that gets turned off too early. The plan follows the reading: a fan that is too small is replaced with one sized to the room, a duct that ends in the attic is re-routed outside, and a fan with no timer gains one. The work is small; the difference it makes to the grout is not.
Steps
Measure the room
Length times width, in square feet. A 5-by-8 bathroom is 40 square feet, and the minimum fan size of 50 CFM applies.
Read the fan's rating
The CFM rating is on the fan itself. A fan rated below the room's size will never clear the air, whatever its age.
Trace the duct
Follow the duct to where it ends. It must end outside the house — through the wall or through the roof — never in the attic.
Check the controls
A timer or a humidity-sensing control runs the fan until the room is dry. A plain switch gets turned off too early.
Run the fan after every shower
During the shower and for 20 to 30 minutes after it. The steam that fills the room during a shower needs half an hour to leave.
Call with what you found
Describe the room's size, the fan's rating, and where the duct ends — and the visit is planned from that description.